Osborne, S. ORCID: https://orcid.org/0000-0002-2826-0627 and Reynolds, S. and George, N. and Lindemayer, F. and Gill, A. and Chalmers, M. (2007) Challenging endoscopy reprocessing guidelines: a prospective study investigating the safe shelf life of flexible endoscopes in a tertiary gastroenterology unit. Endoscopy, 39 (9). pp. 825-830. ISSN 0013-726X


Abstract

Background and study aims: Professional practice guidelines for endoscope reprocessing recommend reprocessing endoscopes between each case and proper storage following reprocessing after the last case of the list. There is limited empirical evidence to support the efficacy of endoscope reprocessing prior to use in the first case of the day; however, internationally, many guidelines continue to recommend this practice. The aim of this study is to estimate a safe shelf life for flexible endoscopes in a high-turnover gastroenterology unit.

Materials and methods: In a prospective observational study, all flexible endoscopes in active service during the 3-week study period were microbiologically sampled prior to reprocessing before the first case of the day (n = 200). The main outcome variables were culture status, organism cultured, and shelf life.

Results: Among the total number of useable samples (n = 194), the overall contamination rate was 15.5 %, with a pathogenic contamination rate of 0.5%. Mean time between last case one day and reprocessing before the first case on the next day (that is, shelf life) was 37.62 h (SD 36.47). Median shelf life was 18.8 h (range 5.27 -165.35 h). The most frequently identified organism was coagulase-negative Staphylococcus, an environmental nonpathogenic organism.

Conclusions: When processed according to established guidelines, flexible endoscopes remain free from pathogenic organisms between last case and next day first case use. Significant reductions in the expenditure of time and resources on reprocessing endoscopes have the potential to reduce the restraints experienced by high-turnover endoscopy units and improve service delivery.


Statistics for USQ ePrint 42950
Statistics for this ePrint Item
Item Type: Article (Commonwealth Reporting Category C)
Refereed: Yes
Item Status: Live Archive
Additional Information: Permanent restricted access to Published version in accordance with the copyright policy of the publisher.
Faculty/School / Institute/Centre: No Faculty
Faculty/School / Institute/Centre: No Faculty
Date Deposited: 09 Aug 2021 05:48
Last Modified: 09 Aug 2021 05:48
Fields of Research (2008): 11 Medical and Health Sciences > 1110 Nursing > 111003 Clinical Nursing: Secondary (Acute Care)
Fields of Research (2020): 42 HEALTH SCIENCES > 4205 Nursing > 420501 Acute care
Identification Number or DOI: https://doi.org/10.1055/s-2007-966766
URI: http://eprints.usq.edu.au/id/eprint/42950

Actions (login required)

View Item Archive Repository Staff Only