Development of a high exposure underwater solar UV dosimeter

Schouten, Peter and Parisi, Alfio and Turnbull, David J. (2006) Development of a high exposure underwater solar UV dosimeter. In: 17th National Congress of the Australian Institute of Physics, 3-8 Dec 2006, Brisbane, Australia.

Metadata

HTML CitationEndNoteDublin CoreReference Manager

Full text available as:

[img]
Preview
PDF - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
16Kb

Official URL: http://www.aip.org.au/news/105

Abstract

[Abstract]: The penetration and distribution of the Solar Ultraviolet Radiation (UV) field in any natural underwater environment depends on the column depth and dissolved organic carbon (DOC) level of the water, and therefore the capability of the UV to cause biological damage to the aquatic biota is also dependent upon these parameters. Several solid-state chemical dosimeters have been fabricated and tested to measure the underwater UV, and in turn quantify the relationship between water column depth and DOC levels to the underwater UV field distribution. However, these dosimeters have only had the ability to measure UV exposures over short temporal increments, thus limiting the scope of the data. It has now become necessary to build upon this initial research and develop a chemical dosimeter that is capable of measuring long-term UV exposure in any type of underwater environment. Poly (2,6-dimethyl-1, 4-phenylene oxide) (PPO) has been identified and selected as a prime candidate for this objective. The optical properties of PPO have already been tested in air. However, before being deployed for trials in actual marine environments, the immersed optical properties of the PPO dosimeter have to be tested in a controlled laboratory environment using solar simulation techniques in order to confirm the suitability of PPO for this purpose. The optical properties that have been investigated to date include the dose response, spectral response, angular variation and dark reaction. In addition to this, the effects of the attachment of a neutral density filter (NDF) to the PPO dosimeter and its subsequent optical properties have been examined in detail. This presentation will deliver these results and will also discuss the future directions that this research will take.

Item Type:Conference or Workshop Item (Commonwealth Reporting Category E) (Poster)
Additional Information:Poster presentation. Abstract only available. No evidence of copyright restrictions on web site.
Uncontrolled Keywords:high exposure, underwater solar UV dosimeter, underwater solar ultraviolet dosimeter, solar ultraviolet radiation field, solar UV radiation field, underwater
Fields of Research (FOR2008):02 Physical Sciences > 0299 Other Physical Sciences > 029999 Physical Sciences not elsewhere classified
04 Earth Sciences > 0401 Atmospheric Sciences > 040103 Atmospheric Radiation
Subjects:240000 Physical Sciences > 249900 Other Physical Sciences > 249999 Physical Sciences not elsewhere classified
Socio-Economic Objective (SEO2008):UNSPECIFIED
ID Code:1647
Deposited By:
Deposited On:11 Oct 2007 10:49
Last Modified:01 Sep 2011 11:09

Archive Staff Only: edit this record